How To Clean The Stenter

The Stenter hits the oven button to enter the heating system interface, and sets the heating temperature to 150 degrees, the circulating fan power to 50%, and the exhaust fan is manually controlled and exhausts at 100% power.

After tentering and machining the cloth, introduce the guide cloth to the operating table, tear the guide cloth apart, click the cloth feed control button to red, and close the upper needle protection entry button to "0".  Start the rear half of the machine, stop when the cloth guide head reaches the cloth outlet overfeed roller, connect the cloth guide with the guide belt, turn off the cooling drum tension motor to "0" and start the rear half of the machine until the cloth guide completely exits the cloth rack and stops.  Turn off the cloth output main control button to red and start the machine to idle the chain.

The Stenter hits the oven button to enter the heating system interface, and sets the heating temperature to 150 degrees, the circulating fan power to 50%, and the exhaust fan is manually controlled and exhausts at 100% power. This can effectively remove the residual moisture in the oven, thus playing a role in maintaining the oven.  Turn off the heating system after about 30 minutes of operation, and let the circulating fan and exhaust fan continue to operate until the temperature in the oven drops below 100 degrees before turning off.  Turn OFF the main control switch of the power supply of the power cabinet, the computer automatically stores the processing data and then turns off to clean the whole machine.

Click the schematic icon of circulating fan of tenter to enter the power setting window of circulating fan, click the total button of circulating fan to pop up the power setting window of circulating fan, click the number box on the white bottom to pop up the number keypad, enter the required output power value, and press confirm.

The tenter clicks the schematic icon of the exhaust fan in the upper left corner or upper right corner to enter the power setting window of the exhaust fan, clicks the manual control button and confirms it, and clicks the white number box to pop up the keypad to enter the required value and confirm it.  If the automatic control button is clicked and confirmed, the ventilator will automatically adjust the power of the ventilator.

Click the numerical box of the temperature displayed in the oven simulation icon to enter the heating window, click the heating total to set the heating temperature, or set the heating temperature of each oven separately.  When the heating temperature is below 90 degrees, click the small fire icon to heat, and when the heating temperature is above 90 degrees, click the large fire icon to heat and confirm.

Start the front half of the machine, open the upper needle protection entrance button to "1" after the cloth guide passes through the upper needle protection entrance, stop when the cloth guide oven reaches the cloth outlet overfeed roller, and connect the cloth guide with the cloth guide of the cloth outlet part.  Click the main control button of the cloth outlet mechanism to turn green, turn on the motors of the cloth outlet part to "1" (except for the cooling cylinder tension motor switch), restart the machine, introduce the cloth guide into the cloth outlet frame, and stop the machine.  Turn on the cooling cylinder tension motor switch to "1". 